3255804
Ground Wire
Cummins®

AVAILABLE

Cummins®

Ships within 1-3 business days

$87.95 $104.66

This truck part is made by Cummins®. We guarantee that all of our parts are from the OEM (original equipment manufacturer), ensuring a proper fit and quality manufacturing.


DESCRIPTION

The Cummins 3255804 Ground Wire is a specialized component designed for use in commercial truck electrical systems. Its purpose is to provide a reliable electrical ground connection, which is vital for the safe and efficient operation of the vehicle’s electrical components. This part is part of Cummins Inc.’s extensive lineup of automotive parts, known for their quality and performance in demanding applications.

Basic Concepts of Ground Wires

Ground wires serve as a pathway for electrical current to return to the earth, completing the electrical circuit. In vehicle electrical systems, ground wires play a role in ensuring that electrical components function correctly and safely. They help dissipate static electricity, protect against electrical surges, and maintain the overall integrity of the electrical system. Proper grounding is fundamental to preventing electrical malfunctions and ensuring the safety of the vehicle’s occupants and cargo 1.

Purpose of the Cummins 3255804 Ground Wire

The Cummins 3255804 Ground Wire is specifically designed to enhance the electrical system’s reliability in commercial trucks. It plays a role in maintaining electrical integrity by providing a stable and low-resistance path for electrical current to return to the vehicle’s chassis or battery. This ensures that electrical components operate within their designed parameters, reducing the risk of malfunctions or failures. Additionally, the ground wire contributes to the safety of the electrical system by helping to prevent electrical shocks and fires caused by faulty grounding.

Key Features

The Cummins 3255804 Ground Wire is constructed from high-quality materials, ensuring durability and performance in harsh commercial truck environments. Its design includes features such as corrosion-resistant coatings and robust insulation, which enhance its longevity and reliability. The wire is also engineered to meet the specific electrical requirements of commercial trucks, providing optimal conductivity and safety.

Benefits of Using the Cummins 3255804 Ground Wire

Utilizing the Cummins 3255804 Ground Wire offers several advantages. It provides improved electrical conductivity, ensuring that electrical components receive a consistent and reliable ground connection. This enhances the overall performance and safety of the vehicle’s electrical system. Additionally, the ground wire’s durable construction and corrosion-resistant properties contribute to its reliability in demanding applications, reducing the need for frequent replacements or repairs.

Installation Considerations

When installing the Cummins 3255804 Ground Wire, it is important to follow guidelines and best practices to ensure proper functionality and safety. This includes routing the wire away from moving parts and heat sources, securing it with appropriate attachment points, and ensuring compliance with manufacturer recommendations. Proper installation helps maintain the electrical system’s integrity and prevents potential issues related to poor grounding.

Maintenance and Inspection

Routine maintenance and inspection of the Cummins 3255804 Ground Wire are crucial for ensuring ongoing performance and safety. This includes checking for signs of corrosion, damage, or loose connections. Regular inspections help identify potential issues before they lead to electrical malfunctions or safety hazards. Maintaining the ground wire in good condition contributes to the overall reliability of the vehicle’s electrical system.

Troubleshooting Common Issues

Common problems associated with ground wires in commercial trucks can include corrosion, loose connections, or damage to the wire itself. Troubleshooting these issues involves inspecting the ground wire for visible signs of wear or damage, ensuring secure connections, and addressing any corrosion with appropriate cleaning and protective measures. Effective troubleshooting helps maintain the electrical system’s integrity and prevents potential safety hazards.

Safety Precautions

When working with electrical systems and ground wires in commercial trucks, it is important to follow safety precautions to prevent accidents and ensure personal safety. This includes wearing appropriate personal protective equipment, ensuring the vehicle’s battery is disconnected before working on the electrical system, and following manufacturer guidelines for handling and installation. Adhering to safety precautions helps protect both the technician and the vehicle from electrical hazards.

Cummins Overview

Cummins Inc. is a global power leader that designs, manufactures, and distributes engines, filtration, and power generation products. With a history spanning over a century, Cummins has established a reputation for quality, innovation, and reliability in the commercial vehicle industry. The company’s product offerings include a wide range of components and systems designed to meet the demanding requirements of commercial trucks and other heavy-duty applications.

Role of Part 3255804 Ground Wire in Engine and Brake Systems

The Ground Wire part 3255804, manufactured by Cummins, is an essential component for ensuring electrical safety and efficiency across various engine models. This part is integral to the ISM CM570, M11 CELECT PLUS, and QSM11 CM570 engines, playing a role in the electrical system of these engines.

In the ISM CM570 and QSM11 CM570 engines, the Ground Wire part 3255804 is strategically positioned to provide a reliable path for electrical current to return to the battery, thereby preventing electrical noise and potential damage to sensitive electronic components. This placement is important for maintaining the integrity of the engine’s electrical system and ensuring optimal performance.

Similarly, in the M11 CELECT PLUS engine, the Ground Wire part 3255804 serves the same fundamental purpose. It ensures that electrical current flows correctly and safely, reducing the risk of electrical faults and enhancing the overall reliability of the engine. This part is designed to withstand the demanding conditions of engine operation, providing a durable and effective grounding solution.

Overall, the Ground Wire part 3255804 is a vital component for the ISM CM570, M11 CELECT PLUS, and QSM11 CM570 engines, contributing to the safety and efficiency of their electrical systems.

Conclusion

The Cummins 3255804 Ground Wire is a critical component in the electrical systems of commercial trucks, ensuring reliable and safe operation of electrical components. Its high-quality construction, corrosion-resistant features, and optimal conductivity make it a durable and effective solution for grounding in demanding environments. Proper installation, maintenance, and adherence to safety precautions are essential to maximize the benefits of this part and ensure the overall integrity and safety of the vehicle’s electrical system.


  1. Composite Materials Handbook Volume 4 Metal Matrix Composites, SAE International, 2013.

SPECIFICATIONS

Hazardous Material
Non-Hazardous (NOI, ICE/Auto)
Package Dimensions
6.8 x 5.2 x 0.7 in
Weight
0.16 lb
* This information is provided as is and may be out of date. Please contact us or the manufacturer to verify warranty coverage.
* Variable geometry turbocharger and electronic actuator repairs are not eligible to be claimed as over-the-counter under New or ReCon parts warranty for parts installed after October 1, 2018.
* Diesel Oxidation Catalyst (DOC), Diesel Particulate Filter (DPF), Selective Catalyst Reduction (SCR) catalyst, and Electronic Control Module (ECM) repairs are not eligible to be claimed as over-the-counter under New or ReCon parts warranty for parts installed after January 1, 2020.
* These restrictions are only applicable to New parts and ReCon parts coverages for the components listed above sold to a customer in the US or Canada. All other coverages are excluded. All other regions are excluded.