This truck part is made by Cummins®. We guarantee that all of our parts are from the OEM (original equipment manufacturer), ensuring a proper fit and quality manufacturing.
We honor the warranty provided by the original equipment manufacturer.
Introduction
The Cummins 191980 Water Transfer Tube is a component designed for use in commercial trucks. It serves a specific function within the vehicle’s cooling system, contributing to the overall efficiency and reliability of the truck’s engine operation. Understanding its purpose and significance is fundamental for maintaining optimal engine performance.
Basic Concepts of Water Transfer Tubes
A water transfer tube is a conduit within a truck’s cooling system that facilitates the movement of coolant between the engine and the radiator. Its operation is integral to maintaining engine temperature within a specified range, ensuring that the engine does not overheat during operation. The coolant absorbs heat from the engine and transfers it to the radiator, where it is dissipated into the atmosphere 1.
Purpose of the 191980 Water Transfer Tube
This Cummins part is engineered to play a role in the truck’s cooling system by transferring coolant between the engine and radiator. This transfer is vital for dissipating heat generated by the engine, thereby maintaining a stable operating temperature and preventing potential damage from overheating.
Key Features
The 191980 is constructed from materials that offer durability and resistance to the corrosive effects of coolant. Its design includes precise fittings and connections that ensure a secure and leak-free installation. Additionally, the tube may feature reinforced sections to withstand the pressure exerted by the coolant as it circulates through the system.
Benefits
The use of the 191980 offers several advantages. It provides improved coolant flow, which enhances the efficiency of heat dissipation from the engine. This results in better engine protection against overheating and contributes to the overall reliability of the truck, especially under demanding operating conditions 2.
Installation Considerations
When installing this part, it is important to ensure compatibility with the specific truck model and engine type. Proper installation involves following manufacturer guidelines to secure the tube in place and verify that all connections are tight and free from leaks. This ensures the tube functions effectively within the cooling system.
Troubleshooting Common Issues
Common issues with water transfer tubes may include leaks or blockages. To address these problems, it is advisable to inspect the tube and connections for signs of wear or damage. Cleaning the tube and ensuring that all fittings are correctly installed can help resolve many issues. Regular checks can prevent more serious problems from developing.
Maintenance Tips
To maintain the 191980, routine inspections should be conducted to check for any signs of wear, corrosion, or leaks. Cleaning the tube as part of regular coolant system maintenance can also help ensure its longevity and optimal performance. Following these practices can contribute to the efficient operation of the truck’s cooling system.
Cummins Corporation
Cummins Inc. is a well-established manufacturer in the commercial truck industry, known for its range of engine and component offerings. The company has a history of providing reliable and high-quality products, which has earned it a reputable standing among truck operators and maintenance professionals.
Cummins Water Transfer Tube 191980 Compatibility
The Cummins Water Transfer Tube, part number 191980, is a component in the cooling system of certain engines, ensuring efficient heat transfer and maintaining optimal engine temperature. This part is designed to fit seamlessly within the architecture of specific Cummins engines, facilitating the movement of coolant between the engine block and the radiator.
V28 Engines
The V28 engine series, known for its robust design and high performance, integrates the Water Transfer Tube 191980 as a vital part of its cooling system. This tube is engineered to withstand the high pressures and temperatures typical of V28 engines, ensuring reliable operation and longevity. The precise fit and design of this component are crucial for maintaining the engine’s efficiency and preventing overheating, which can lead to significant performance degradation or engine damage.
Grouping by Application
In applications where the V28 engine is utilized, such as in heavy-duty trucks, construction equipment, and industrial machinery, the Water Transfer Tube 191980 plays a pivotal role. Its compatibility with these engines is a testament to Cummins’ commitment to providing high-quality, durable parts that meet the demanding requirements of these industries. The seamless integration of this part into the engine’s cooling system underscores its importance in ensuring the engine operates at peak efficiency, regardless of the demanding conditions it may face.
Role of Part 191980 Water Transfer Tube in Engine Systems
The 191980 is an essential component in the efficient operation of various engine systems, particularly those involving the cooling and lubrication of engine parts. This component facilitates the transfer of water between different parts of the engine system, ensuring that all components receive the necessary cooling and lubrication to function optimally.
In the context of the Cooler Lubricating Filter and Cooler Lubricating Oil Filter, the Water Transfer Tube plays a significant role in maintaining the temperature of the lubricating oil. By transferring water to these filters, it helps in dissipating heat, which is vital for the longevity and performance of the lubrication system.
When integrated with the Cooler Lubricating Oil Mounting Filter and Lubricating Oil Mounting Filter Cooler, the tube ensures a consistent flow of coolant, which is essential for the effective operation of these filters. This consistent flow helps in maintaining the oil at an optimal temperature, thereby enhancing the efficiency of the lubrication process.
The Filter and Lubricating Oil components also benefit from the Water Transfer Tube. By ensuring a steady supply of coolant to these parts, the tube helps in preventing overheating, which can lead to a breakdown of the lubricating oil and subsequent engine damage.
In systems involving the Filter Cooler and Filter-Cooler Mounting, the tube’s role is to provide a reliable coolant transfer mechanism. This is particularly important in high-performance engines where the cooling demands are greater.
The Lube Oil Filter & Co and Mounting Lubricating Oil Cooler F components are also reliant on the efficient operation of the Water Transfer Tube. These components require a consistent coolant flow to function effectively, and the tube ensures that this flow is maintained.
Lastly, in Plumbing and Oil Cooler Water systems, the Water Transfer Tube is instrumental in ensuring that the coolant reaches all necessary points within the engine. This is vital for the overall cooling efficiency of the engine, helping to maintain optimal operating temperatures and prevent overheating.
Conclusion
In summary, the 191980 is a key component in the cooling and lubrication systems of engines. Its role in transferring water to various components ensures that these parts operate within their optimal temperature ranges, contributing to the overall efficiency and longevity of the engine.
SPECIFICATIONS
RECOMMENDED PARTS
* Variable geometry turbocharger and electronic actuator repairs are not eligible to be claimed as over-the-counter under New or ReCon parts warranty for parts installed after October 1, 2018.
* Diesel Oxidation Catalyst (DOC), Diesel Particulate Filter (DPF), Selective Catalyst Reduction (SCR) catalyst, and Electronic Control Module (ECM) repairs are not eligible to be claimed as over-the-counter under New or ReCon parts warranty for parts installed after January 1, 2020.
* These restrictions are only applicable to New parts and ReCon parts coverages for the components listed above sold to a customer in the US or Canada. All other coverages are excluded. All other regions are excluded.