This truck part is made by Cummins®. We guarantee that all of our parts are from the OEM (original equipment manufacturer), ensuring a proper fit and quality manufacturing.
We honor the warranty provided by the original equipment manufacturer.
The Cummins 3076224 Water Transfer Tube is a component designed for use in commercial trucks. Its purpose is to facilitate the transfer of coolant between the engine and the radiator, playing a role in maintaining optimal engine temperature. This part is significant in the operation of commercial trucks as it contributes to the efficiency and reliability of the engine cooling system 1.
Function and Operation
The Water Transfer Tube operates within the truck’s cooling system by providing a conduit for coolant to flow from the engine to the radiator and back. This circulation helps dissipate heat generated by the engine, ensuring that the engine operates within its designed temperature range. The tube is positioned to connect critical points in the cooling system, allowing for efficient coolant transfer 2.
Key Features
The design and construction of the 3076224 Water Transfer Tube include several features that enhance its performance. It is made from durable materials that can withstand the pressures and temperatures of the cooling system. The tube’s dimensions are engineered to accommodate the flow rates required for effective cooling. Additionally, the tube may incorporate unique characteristics such as reinforced joints or specialized coatings to improve durability and performance 3.
Benefits
The advantages provided by the 3076224 Water Transfer Tube include improved coolant flow, which contributes to enhanced engine cooling efficiency. This can lead to more stable engine temperatures under various operating conditions. Furthermore, the tube’s design may contribute to overall engine performance and longevity by ensuring that the engine remains within its optimal temperature range.
Installation and Maintenance
For proper installation of the Water Transfer Tube, it is important to follow manufacturer guidelines to ensure that it is securely fitted and properly aligned within the cooling system. Recommended maintenance practices include regular inspection for signs of wear or damage, ensuring that connections are tight, and replacing the tube if any issues are detected. These practices help maintain optimal performance and prevent potential cooling system failures.
Troubleshooting
Common problems associated with the Water Transfer Tube may include leaks or blockages. Diagnostic procedures for identifying issues can involve visual inspection, pressure testing, and monitoring coolant flow. Recommended solutions for resolving malfunctions or leaks may include repairing or replacing the tube, depending on the severity of the issue.
Manufacturer Information
Cummins Inc. is a well-established company with a history of producing components for commercial vehicles. The company is recognized in the automotive industry for its commitment to quality and innovation. Cummins components, including the 3076224 Water Transfer Tube, are designed to meet the demanding requirements of commercial truck applications.
Water Transfer Tube (Part 3076224) in Cummins Engines
The Water Transfer Tube, identified by the part number 3076224, is a critical component in the cooling systems of various Cummins engines. This part is integral to maintaining optimal engine temperature by facilitating the transfer of coolant between different parts of the engine’s cooling system.
N14 CELECT PLUS and N14 MECHANICAL Engines
In the N14 CELECT PLUS and N14 MECHANICAL engines, the Water Transfer Tube is designed to ensure efficient coolant flow, which is essential for preventing overheating and ensuring the engine operates within its specified temperature range. The placement and design of this tube are engineered to handle the specific thermal demands of these engines, providing a reliable pathway for coolant to circulate effectively.
The Water Transfer Tube in these engines is typically located in areas where coolant needs to be redirected to maintain uniform temperature distribution. Its design allows for the smooth transfer of coolant, which is crucial for the longevity and performance of the engine. The material and construction of the tube are chosen to withstand the high pressures and temperatures encountered in the engine’s cooling system, ensuring durability and reliability over time.
By integrating this part into the cooling system architecture, Cummins ensures that both the N14 CELECT PLUS and N14 MECHANICAL engines can maintain their operational efficiency and reliability, even under demanding conditions.
Role of Part 3076224 Water Transfer Tube in Engine Systems
The part 3076224 Water Transfer Tube is integral to the efficient operation of engine cooling systems. It facilitates the movement of coolant between various components, ensuring optimal thermal management.
In conjunction with the thermostat housing, the Water Transfer Tube plays a significant role. The thermostat housing regulates the flow of coolant based on engine temperature. The Water Transfer Tube ensures a consistent supply of coolant to the thermostat housing, allowing it to function effectively. This synergy helps maintain the engine at its ideal operating temperature, enhancing performance and longevity.
Additionally, the Water Transfer Tube connects to the water pump, which circulates coolant throughout the engine. This connection is vital for uniform coolant distribution, preventing hotspots and ensuring even cooling across all engine components.
The tube also interfaces with the radiator, where coolant is cooled before being recirculated. This continuous loop, supported by the Water Transfer Tube, is essential for dissipating heat generated during engine operation.
Furthermore, the Water Transfer Tube links to the engine block and cylinder head, providing coolant to these high-stress areas. This helps in managing the temperature of critical engine parts, reducing the risk of overheating and potential damage.
Conclusion
In summary, the part 3076224 Water Transfer Tube is a key component in the engine’s cooling system, working in tandem with the thermostat housing, water pump, radiator, engine block, and cylinder head to maintain engine efficiency and reliability.