DESCRIPTION

The Cummins 4917140 Water Transfer Tube is a component designed for use in commercial trucks. It plays a role in the engine cooling system by ensuring that the engine operates within optimal temperature ranges. This part is integral to maintaining the efficiency and reliability of the truck’s engine, contributing to overall vehicle performance and longevity.

Basic Concepts of Water Transfer Tubes

A Water Transfer Tube is a component within the engine cooling system that facilitates the movement of coolant between different parts of the engine. Its function is to ensure that coolant is evenly distributed, which helps in dissipating heat generated by the engine. The tube operates by allowing coolant to flow through it, transferring heat away from critical engine components and towards the radiator where it can be cooled 1.

Purpose of the 4917140 Water Transfer Tube

The 4917140 Water Transfer Tube plays a role in the operation of a truck by transferring coolant throughout the engine. This process is vital for maintaining engine temperature within specified limits. By ensuring that coolant reaches all necessary areas, the tube helps prevent overheating, which can lead to engine damage. Its function is to support the overall cooling efficiency of the engine, contributing to stable and reliable performance under various operating conditions 2.

Key Features

The 4917140 Water Transfer Tube is characterized by its robust design and the materials used in its construction. It is engineered to withstand the high pressures and temperatures typical of engine environments. The tube is made from durable materials that resist corrosion and wear, ensuring long-term performance. Additionally, its design may include features that enhance coolant flow and reduce the likelihood of leaks, contributing to its effectiveness in the cooling system 3.

Benefits

The benefits provided by the 4917140 Water Transfer Tube include improved engine cooling efficiency, which is crucial for maintaining optimal engine performance. Its durable construction ensures reliability over time, reducing the need for frequent replacements. The tube’s design contributes to efficient coolant distribution, which helps in maintaining consistent engine temperatures and preventing overheating 4.

Installation Process

Installing the 4917140 Water Transfer Tube involves several steps to ensure it is properly fitted and functions correctly. The process typically requires specific tools and may involve disconnecting the old tube, cleaning the area, and securing the new tube in place. Detailed instructions should be followed to ensure that the installation is performed correctly, which may include torquing bolts to specified levels and checking for proper alignment.

Common Issues and Troubleshooting

Common issues with the 4917140 Water Transfer Tube may include leaks, blockages, or corrosion. Troubleshooting these issues involves inspecting the tube for signs of damage or wear, checking connections for tightness, and ensuring that the coolant flow is not obstructed. Solutions may range from cleaning and repairing minor damage to replacing the tube if it is severely compromised.

Maintenance Tips

To ensure the optimal performance and longevity of the 4917140 Water Transfer Tube, regular maintenance is recommended. This includes inspecting the tube for signs of wear or damage, checking connections for leaks, and ensuring that the coolant system is free of contaminants. Cleaning the tube and its connections as part of routine engine maintenance can help prevent issues and ensure efficient operation.

Cummins Overview

Cummins Inc. is a global power leader that designs, manufactures, and distributes engines, filtration, and power generation products. With a history of innovation and quality, Cummins serves commercial, industrial, and automotive markets. The company is known for its comprehensive product offerings and strong reputation in the commercial truck industry, providing solutions that enhance vehicle performance and reliability.

Role of Part 4917140 Water Transfer Tube in Engine Systems

The 4917140 Water Transfer Tube is an essential component in the efficient operation of engine cooling systems. It is specifically designed to facilitate the smooth and reliable transfer of coolant between various parts of the engine, ensuring optimal thermal management.

Interaction with Thermostat Housing

When integrated with the thermostat housing, the Water Transfer Tube plays a significant role in regulating the flow of coolant. The thermostat housing contains the thermostat, which monitors the engine temperature and controls the flow of coolant into the engine block. The Water Transfer Tube connects to the thermostat housing, allowing coolant to be directed either to the engine block for cooling or recirculated back to the radiator when the engine is cold. This ensures that the engine operates within the desired temperature range, preventing overheating and enhancing overall engine performance.

Enhanced Cooling Efficiency

By providing a dedicated pathway for coolant transfer, the Water Transfer Tube enhances the efficiency of the cooling system. It ensures that coolant reaches the thermostat housing promptly, allowing for quicker response times in temperature regulation. This is particularly important in high-performance engines where maintaining precise temperature control is vital for efficiency and longevity.

Reliable Coolant Circulation

The design of the Water Transfer Tube is tailored to withstand the pressures and temperatures within the engine cooling system. Its reliable construction ensures consistent coolant circulation, which is essential for preventing hot spots and ensuring uniform cooling across the engine components. This reliability is key in maintaining the integrity of the engine over time.

Integration with Other Components

Beyond its interaction with the thermostat housing, the Water Transfer Tube also connects to other critical components such as the water pump, radiator, and engine block. This interconnected network ensures that coolant is efficiently distributed throughout the engine, facilitating effective heat dissipation and maintaining engine stability under various operating conditions.

Conclusion

In summary, the 4917140 Water Transfer Tube is a vital element in the engine’s cooling system, working in tandem with the thermostat housing and other components to ensure reliable and efficient coolant transfer. This contributes to the overall performance and durability of the engine.


  1. Lakshminarayanan, P. A., & Aghav, Y. V. (2010). Modelling Diesel Combustion. Springer Science.

  2. Awari, G. K., Kumbhar, V. S., & Tirpude, R. B. (2011). Automotive Systems Principles and Practice. CRC Press.

  3. Livesey, A. (2000). The Repair of Vehicle Bodies. Elevier.

  4. Duffy, O. C., & Wright, G. (2016). Fundamentals of Medium-Heavy Duty Commercial Vehicle Systems. Jones Bartlett Learning.

RELATED PARTS

SPECIFICATIONS

Package Dimensions
26.0 x 14.0 x 25.0 in
Weight
1.548 lbs
* This information is provided as is and may be out of date. Please contact us or the manufacturer to verify warranty coverage.
* Variable geometry turbocharger and electronic actuator repairs are not eligible to be claimed as over-the-counter under New or ReCon parts warranty for parts installed after October 1, 2018.
* Diesel Oxidation Catalyst (DOC), Diesel Particulate Filter (DPF), Selective Catalyst Reduction (SCR) catalyst, and Electronic Control Module (ECM) repairs are not eligible to be claimed as over-the-counter under New or ReCon parts warranty for parts installed after January 1, 2020.
* These restrictions are only applicable to New parts and ReCon parts coverages for the components listed above sold to a customer in the US or Canada. All other coverages are excluded. All other regions are excluded.